VIMS - Verified Industrial Maintenance Solutions        Single Channel Interface Module with Triple Output HS-535 | Hansford Sensors

HS-535 Single Channel Interface Module with Triple Output

Single Channel Interface Module with Triple Output HS-535

 

Key Features:

  • Enveloped ‘g’ Output
  • Input – 100mV/g constant current accelerometers (HS-100 Series)
  • Output – AC and 0-10 Volts proportional to either RMS Velocity, Envelope ‘g’, AC ‘g’ via BNC (for data collection), or AC Enveloped ‘g’
   
Technical Performance
Input: 100 mV/g constant current accelerometer
 G (RMS): 10Hz to 5kHz
Frequency Range: 2 Hz to 10 kHz (-3dB)
gE Filters: 10Hz to 1.5 kHz or 3.5 kHz or 5 kHz (-3dB)
2-pole Butterworth. Set by internal links
Velocity Filters: 10Hz to 1kHz (-3dB) 2-pole Butterworth
Displacement Filters: 10Hz to 40Hz (-3dB) 2-pole Butterworth
 
Mechanical
Case Material: Plastic
Mounting: DIN Rail TS35 (Top Hat)
Dimensions: 134 x 99 x 22.5 mm (H x D x W) including BNC
Connections: Screw Clamp
Conductor Size: 0.5 to 4.0 mm
Weight: 140 gms (nom)
 
Electrical
Power Input: +24 V DC at 50 mA (HS-570 Power Supply Module)
Output 1: 0-10 VDC = 4-20 mA= Velocity or g RMS
 Set by internal link
Output 2: 0-10 VDC or 4-20 mA = g pk or pk to pk or displacement,
see ‘How To Order’ table. Set by internal links
Output 3: (BNC): Buffered acceleration output with DC bias voltage
(nom. 12 VDC)
AC only about 0 V optional – on request
TDX OK: Transducer OK. Outputs 1 & 2 held at 0 V or 2 mA
when in fault
 
Environmental
Operating Temperature Range: 0 to 50ºC
Installation Category (IEC664): II
Equipment Class (IEC536): III
EMC: EN61326-1:2013
   

How to order:

Enquire about HS-535 Single Channel Interface Module with Triple Output

    Send your inquiry via the form below or contact us: info@vims.pl, +48 12 446 40 50


    error

    Pozostań z nami w kontakcie | Let's keep in touch

    Facebook
    YouTube
    LinkedIn
    LinkedIn