VIMS - Verified Industrial Maintenance Solutions        HS-100I Intrinsically Safe Accelerometer- Standard Top- Silicon Cable - VIMS

HS-100I Intrinsically Safe Accelerometer- Standard Top- Silicon Cable

HS-100I Intrinsically Safe Accelerometer – Standard Top –  2 Pin MS

 

Vibration Monitoring with Hansford Sensors

Range of AC 100mV/g accelerometers is designed for use with all types of data collectors and online systems using two-wire constant current method of drive.  The range includes standard, high performance premium and OEM accelerometers, each manufactured to the highest ISO standards and backed by our outstanding technical customer support services.  

Key Features:

  • ATEX approved
  • US/Canada Class I, II, III, Division 1 & 2 approved
  • Various mountings
  • Sealed to IP68
  • Submerged up to 100 metres (10 bar)
  • Includes 5 metres of cable (other lengths available on request)
  • Zener barrier information (MTL *see product 7728+ on page 9 of datasheet)
  • Zener barrier information (P&F)
  • Galvanic isolator information (P&F)
  • For fans, pumps, motors, gearboxes and more
  • Maximum cable lengths
 

Typical Applications:

Fans, pumps, motors, gearboxes, compressore, centrifuges, conveyors, Air handlers, rolls, dryers, presses, cooling, HVAC, spindles, machine tooling, process equipment    
Technical Performance
Mounted Base Resonance: see ‘How To Order’ table
Sensitivity: see: ‘How To Order’ table ± 10% Nominal 80Hz at 22°C
Frequency Response: 2Hz (120cpm) to 10kHz (600kcpm) ± 5%
1.5Hz (90cpm) to 12kHz (720kcpm) ± 10%
0.8Hz (48cpm) to 15kHz (900kcpm) ± 3dB
Isolation: Base isolated
Range: see: ‘How To Order’ table
Transverse Sensitivity: Less than 5%
   
Mechanical
Case Material: Stainless Steel
Sensing Element/Construction: PZT/Compression
Mounting Torque: 8Nm
Weight: 125gms (nominal)
Screened Cable Assembly: see: www.hansfordsensors.com for options
Connector: Silicon
Mounting Threads: see: ‘How To Order’ table
   
Electrical
Electrical Noise: 0.1mg max
Current Range: 0.5mA to 8mA
Bias Voltage: 10 – 12 Volts DC
Settling Time: 2 seconds
Output Impedance: 200 Ohms max.
Case Isolation: >108 Ohms at 500 Volts
   
Environmental
Operating Temperature Range: see: attached certification details
Sealing: IP68
Maximum Shock: 5000g
EMC: EN61326-1:2013
    Typical Frequency Response (at 100mV/g):   How to order:   Certifications:    

Enquire about HS-100I Intrinsically Safe Accelerometer- Standard Top- Silicon Cable



    Send your inquiry via the form below or contact us: info@vims.pl, +48 12 446 40 50



    error

    Pozostań z nami w kontakcie | Let's keep in touch

    Facebook
    YouTube
    LinkedIn
    LinkedIn