VIMS - Verified Industrial Maintenance Solutions        HS-100I Intrinsically Safe Accelerometer- Standard Top- M12 - VIMS

HS-100I Intrinsically Safe Accelerometer- Standard Top- M12

HS-100I Intrinsically Safe Accelerometer – Standard Top –  M12

 

Vibration Monitoring with Hansford Sensors

Range of AC 100mV/g accelerometers is designed for use with all types of data collectors and online systems using two-wire constant current method of drive.  The range includes standard, high performance premium and OEM accelerometers, each manufactured to the highest ISO standards and backed by our outstanding technical customer support services.  

Key Features:

  • Certyfikat ATEX
  • US/Kanada, zezwolenie dla klas I, II, III, dywizji 1 i 2
  • Różne sposoby montażu
  • Szczelność IP67
  • Niewielki koszt kabla
  • Informacje na temat bariery Zenera (MTL *zobacz produkt 7728+ na stronie 9)
  • Informacje na temat bariery Zenera (P&F)
  • Informacje na temat izolacji galwanicznej (P&F)
  • Stosowany przy wentylatorach, pompach, silnikach, przekładniach i innych
  • Maksymalna długość kabli – page 5
 

Typical Applications:

Fans, pumps, motors, gearboxes, compressore, centrifuges, conveyors, Air handlers, rolls, dryers, presses, cooling, HVAC, spindles, machine tooling, process equipment    
Technical Performance
Mounted Base Resonance: see ‘How To Order’ table
Sensitivity: see: ‘How To Order’ table ± 10% Nominal 80Hz at 22°C
Frequency Response: 2Hz (120cpm) to 10kHz (600kcpm) ± 5%
1.5Hz (90cpm) to 12kHz (720kcpm) ± 10%
0.8Hz (48cpm) to 15kHz (900kcpm) ± 3dB
Isolation: Base isolated
Range: see: ‘How To Order’ table
Transverse Sensitivity: Less than 5%
   
Mechanical
Case Material: Stainless Steel
Sensing Element/Construction: PZT/Compression
Mounting Torque: 8Nm
Weight: 125gms (nominal)
Screened Cable Assembly: see: www.hansfordsensors.com for options
Connector: HS-AC010
HS-AC011
Mounting Threads: see: ‘How To Order’ table
   
Electrical
Electrical Noise: 0.1mg max
Current Range: 0.5mA to 8mA
Bias Voltage: 10 – 12 Volts DC
Settling Time: 2 seconds
Output Impedance: 200 Ohms max.
Case Isolation: >108 Ohms at 500 Volts
   
Environmental
Operating Temperature Range: see: attached certification details
Sealing: IP67
Maximum Shock: 5000g
EMC: EN61326-1:2013
    Typical Frequency Response (at 100mV/g):   How to order:   Certifications:    