VIMS - Verified Industrial Maintenance Solutions        HS-420RT Accelerometer 4-20mA - Top Entry- Dual Output (4-20mA & temperature Pt100)- PUR Cable - VIMS

HS-420RT Accelerometer 4-20mA – Top Entry- Dual Output (4-20mA & temperature Pt100)- PUR Cable

HS-420RT Accelerometer 4-20mA velocity with temperature output- PUR Cable

Vibration Monitoring with Hansford Sensors

Our advanced vibration transmitters, or loop powered sensors, are engineered for use with the latest PLC (programmable logic controller), BMS (building management system), or SCADA (supervisory control and data acquisition) technologies, offering sophisticated solutions for condition monitoring and preventative maintenance. The family is available with a variety of different cables.  

Key Features:

  • 4-20mA output proportional to velocity
  • Temperature (Pt100)
  • Various mountings
  • Sealed to IP68
  • Submerged up to 100 metres (10 bar)
  • Includes 5 metres of cable (other lengths available on request)

Typical Applications:

Fans, pumps, motors, gearboxes, compressore, centrifuges, conveyors, Air handlers, rolls, dryers, presses, cooling, VAC, spindles, machine tooling, process equipment  
Technical Performance
Mounted Base Resonance: 5kHz min
Velocity Ranges: see: ‘How To Order’ table ± 10% Nominal 80Hz at 22°C
Frequency Response: 10Hz (600 kcpm) to 1kHz (60kcpm) ± 5% – ISO10816
Isolation: Base isolated
Range: 50g peak
Temperature Output: Pt100 (100Ohm)
Transverse Sensitivity: Less than 5%
 
Mechanical
Case Material: Stainless Steel
Sensing Element/Construction: PZT/Compression
Mounting Torque: 8Nm
Weight: 150gms (nominal)
Screened Cable Assembly: HS-AA005 – non-booted
HS-AA068 or HS-0069 – booted
Mounting Threads: see: ‘How To Order’ table
 
Electrical
Current Output: 4-20mA DC proportional to Velocity Range
Supply Voltage: 15-30 Volts DC (for 4-20mA)
Settling Time: 2 seconds
Output Impedance: Loop Resistance 600 Ohms max. at 24 Volts
Case Isolation: >108 Ohms at 500 Volts
 
Environmental
Operating Temperature Range: -25 to 90ºC
Sealing: IP68
Maximum Shock: 5000g
EMC: EN61326-1:2013
  Typical Frequency Response (at 100mV/g):   How to order:    
Another connection typeImagewww
Top: M12 SEE
Top: PUR Cable SEE
Top: M12 with PT100 SEE
Side: M12  SEE
Side: M12 with PT100 SEE
 

Enquire about HS-420RT Accelerometer 4-20mA - Top Entry- Dual Output (4-20mA & temperature Pt100)- PUR Cable

    Send your inquiry via the form below or contact us: info@vims.pl, +48 12 446 40 50


    error

    Pozostań z nami w kontakcie | Let's keep in touch

    Facebook
    YouTube
    LinkedIn
    LinkedIn