VIMS - Verified Industrial Maintenance Solutions        HS-420IT Accelerometer 4-20mA with Temperature Intrinsically Safe - Top Entry- M12 - VIMS

HS-420IT Accelerometer 4-20mA with Temperature Intrinsically Safe – Top Entry- M12

HS-420ITAccelerometer 4-20mA velocity with with Temperature Intrinsically Safe- M12

Vibration Monitoring with Hansford Sensors Our advanced vibration transmitters, or loop powered sensors, are engineered for use with the latest PLC (programmable logic controller), BMS (building management system), or SCADA (supervisory control and data acquisition) technologies, offering sophisticated solutions for condition monitoring and preventative maintenance. The family is available with a variety of different cables.   Key Features:
  • ATEX approved
  • US/Canada Class I, II, III, Division 1 & 2 approved
  • 4-20mA output proportional to velocity
  • Temperature output
  • Various mountings
  • Sealed to IP67
  • Low cost cable assembly
  • Zener barrier information – 4-20mA
  • Zener barrier information – Temperature
  • Galvanic isolator information – 4-20mA
  • Galvanic isolator information – Temperature
  • Maximum cable lengths – page 5
  Typical Applications: Fans, pumps, motors, gearboxes, compressore, centrifuges, conveyors, Air handlers, rolls, dryers, presses, cooling, VAC, spindles, machine tooling, process equipment  
Technical Performance
Mounted Base Resonance: 5kHz min
Velocity Ranges: see: ‘How To Order’ table ± 10% Nominal 80Hz at 22°C
Frequency Response: 10Hz (600 kcpm) to 1kHz (60kcpm) ± 5% – ISO10816
Isolation: Base isolated
Range: 50g peak
Temperature Output: 100mV/°C- 0-1V
Transverse Sensitivity: Less than 5%
 
Mechanical
Case Material: Stainless Steel
Sensing Element/Construction: PZT/Compression
Mounting Torque: 8Nm
Weight: 150gms (nominal)
Screened Cable Assembly: HS-AC010
HS-AC011
Mounting Threads: see: ‘How To Order’ table
 
Electrical
Current Output: 4-20mA DC proportional to Velocity Range
Supply Voltage: 15-30 Volts DC (for 4-20mA)
Settling Time: 2 seconds
Output Impedance: Loop Resistance 600 Ohms max. at 24 Volts
Case Isolation: >108 Ohms at 500 Volts
 
Environmental
Operating Temperature Range: see: attached certification details
Sealing: IP67
Maximum Shock: 5000g
EMC: EN61326-1:2013
  Typical Frequency Response (at 100mV/g):   How to order:     Certification:

Enquire about HS-420IT Accelerometer 4-20mA with Temperature Intrinsically Safe - Top Entry- M12

    Send your inquiry via the form below or contact us: info@vims.pl, +48 12 446 40 50