VIMS - Verified Industrial Maintenance Solutions        HS-173 AC Premium- Multi-Axial- Side Entry- M12 - VIMS

HS-173 AC Premium- Multi-Axial- Side Entry- M12

HS-173 AC Premium- Multi-Axial- M12

 

Vibration Monitoring with Hansford Sensors

 

Key Features:

  • Fast settling times 1 sec
  • Compact
  • Sealed to IP67
  • Various mountings.
 

Typical Applications:

Building services, Pulp and Paper, Mining, Metals, Utilities, Automotive, Water, Pharmaceutical, Wind.    
Technical Performance
Mounted Base Resonance: see ‘How To Order’ table
Sensitivity: see: ‘How To Order’ table ± 10% Nominal 80Hz at 22°C
Frequency Response: 2Hz (120cpm) to 10kHz (600kcpm) ± 5%
1.5Hz (90cpm) to 12kHz (720kcpm) ± 10%
0.8Hz (12cpm) to 15kHz (900kcpm) ± 3dB
Isolation: Base isolated
Range: see: ‘How To Order’ table
Temperature output: 10 mV/ºC standard 100°C – Option 140°C
Transverse Sensitivity: Less than 5%
 
Mechanical
Case Material: Stainless Steel unless specified Aluminium
Sensing Element/Construction: PZT/Shear
Mounting Torque: 8Nm
Weight: 235g (nominal) – Stainless
115g (nominal) – Aluminium
Screened Cable Assembly: see: www.hansfordsensors.com for options
Connector: HS-AC010
Mounting Threads: see: ‘How To Order’ table
 
Electrical
Electrical Noise: 0.1mg max
Current Range: 0.5mA to 8mA
Bias Voltage: 10 – 12 Volts DC
Settling Time: 1 seconds
Output Impedance: 200 Ohms max.
Case Isolation: >108 Ohms at 500 Volts
 
Environmental
Operating Temperature Range: -55 to 140°C
Sealing: IP67
Maximum Shock: 5000g
EMC: EN61326-1:2013
  Typical Frequency Response (at 100mV/g):   How to order:    
AnotherImagewww
Biaxial- M12  SEE
Round Triaxial- M12  SEE

Enquire about HS-173 AC Premium- Multi-Axial- Side Entry- M12

    Send your inquiry via the form below or contact us: info@vims.pl, +48 12 446 40 50