VIMS - Verified Industrial Maintenance Solutions        HS-100IS Intrinsically Safe Accelerometer- Side Entry- Braided Cable - VIMS

HS-100IS Intrinsically Safe Accelerometer- Side Entry- Braided Cable

HS-100IS Intrinsically Safe Accelerometer – Side Entry –  Braided Cable

 

Vibration Monitoring with Hansford Sensors

Range of AC 100mV/g accelerometers is designed for use with all types of data collectors and online systems using two-wire constant current method of drive.  The range includes standard, high performance premium and OEM accelerometers, each manufactured to the highest ISO standards and backed by our outstanding technical customer support services.  

Key Features:

  • ATEX approved
  • US/Canada Class I, II, III, Division 1 & 2 approved
  • Various mountings
  • Sealed to IP65
  • Armoured protection
  • Includes 5 metres of cable (other lengths available on request)
  • Zener barrier information (MTL *see product 7728+ on page 9 of datasheet)
  • Zener barrier information (P&F)
  • Galvanic isolator information (P&F)
  • For fans, pumps, motors, gearboxes and more
  • Maximum cable lengths
 

Typical Applications:

Fans, pumps, motors, gearboxes, compressore, centrifuges, conveyors, Air handlers, rolls, dryers, presses, cooling, HVAC, spindles, machine tooling, process equipment    
Technical Performance
Mounted Base Resonance: see ‘How To Order’ table
Sensitivity: see: ‘How To Order’ table ± 10% Nominal 80Hz at 22°C
Frequency Response: 2Hz (120cpm) to 10kHz (600kcpm) ± 5%
1.5Hz (90cpm) to 12kHz (720kcpm) ± 10%
0.8Hz (48cpm) to 15kHz (900kcpm) ± 3dB
Isolation: Base isolated
Range: see: ‘How To Order’ table
Transverse Sensitivity: Less than 5%
   
Mechanical
Case Material: Stainless Steel
Sensing Element/Construction: PZT/Compression
Mounting Torque: 8Nm
Weight: 185gms (nominal)
Screened Cable Assembly: see: www.hansfordsensors.com for options
Connector: Braided
Mounting Threads: see: ‘How To Order’ table
   
Electrical
Electrical Noise: 0.1mg max
Current Range: 0.5mA to 8mA
Bias Voltage: 10 – 12 Volts DC
Settling Time: 2 seconds
Output Impedance: 200 Ohms max.
Case Isolation: >108 Ohms at 500 Volts
   
Environmental
Operating Temperature Range: see: attached certification details
Sealing: IP65
Maximum Shock: 5000g
EMC: EN61326-1:2013
    Typical Frequency Response (at 100mV/g):   How to order:   Certifications:    