VIMS - Verified Industrial Maintenance Solutions        CMCP525 Acceleration Transmitter/Monitor - VIMS

CMCP525 Acceleration Transmitter/Monitor

CMCP525 Acceleration Transmitter/Monitor

  Key features:
  • Accelerometer Input
  • Acceleration Output (g’s)
  • Transmitter or Monitor
  • RMS or Peak Detection
  • 100 mV/g Input Std.
  • 4-20 mA Output
  • 2 Buffered Outputs
  • 5 Selectable Ranges
  • Fault (OK) Detection
  • CSA & UL C1,D2
  • DIN Rail Mount
  • Optional HP & LP Filters
  The CCMCP500 Transmitter Approval LabelMCP525 Acceleration In/Acceleration Out Transmitter is available in either “Peak” or “True RMS” signal detection versions. The CMCP525 is compatible with all voltage output accelerometers, and provides a 4-20 mA output proportional to the overall measurement. Each unit provides constant current power for the accelerometer, checks for faults, processes the vibration signal to determine overall amplitude, and outputs a 4-20 mA DC current that is proportional to a user selected range of 5, 10, 15, 20 or 25 g’s with a 100 mv/g Input. CSA and UL Class 1, Div 2, B-D Approved.
The Optional Alarm Module provides OK, Alert and Danger Relays, selectable time delay, trip multiply, bypass and 0 to 5 VDC outputs for displays. The relay outputs can be used to trigger machine shut-down or other alarms. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.
Custom Input and Output Calibrations are Available on Request.
Buffered Output: A BNC connector mounted on the front of the unit provides access to the buffered transducer output signal. This includes both the unfiltered vibration signal, and the DC bias voltage. Portable test equipment or analyzers can be connected to this output without disturbing other system outputs. Fault Detection: On board fault detection circuitry continuously monitors the transducer for normal operation. If a fault occurs, the output current is reduced to <2 mA to indicate the fault to the readout system. A green LED on the front of the unit is turned off to provide a local indication of the fault. Filters: For applications that require monitoring specific frequency bands, optional high-pass and low-pass filters can be specified. These filters are modular and can be installed by the factory or in the field. Each module attenuates out-of-band signals at a rate of approximately 24 dB/octave. Corner frequencies from 2 Hz to 20 kHz may be specified. Filter modules may be cascaded to form higher order filters or to create a band-pass response. Filtering does not effect the buffered transducer output. Alarms relays and trip multiply are available with the Monitor version CMCP500 Monitor Approval LabelAlarms – The CMCP500A Series Monitors have two independent set points, with LED alarm indicators and output relay contacts (Alert and Danger). Set points are adjustable via potentiometer, from 0 to 110% of full scale. Each has an adjustable delay of 1 to 10 seconds. SPST Relay contacts are rated 5 Amps @ 30 Vdc or 250 Vac for resistive loads. Relay contacts can be independently configured by the user for either Normally Open (NO) (Standard) or Normally Closed (NC) operation. Relays are normally de-energized and can be configured for latching or non-latching (standard) operation. Latched alarms may be reset locally or by remote contact closure.
Trip Multiply – The monitors have set point multiplication of 3X via contact closure (2X available). To avoid tripping the alarms during machine start-up.
Technical Specs:
 
Electrical
Input: Accelerometer (100 mv/g)
Power: +24 Vdc @ 45 mA max. (30 mA typical)
Protection: Reverse polarity and transient protection
Frequency Response (wo/filters): (-3 dB) 2 Hz to 20 kHz
Buffered Output: BNC Connector 0-20 kHz
Accuracy: 0.5 % of Full Scale Range
Output: 4-20 mA proportional to the full scale range
Maximum Load: 600 Ohms Resistive
Case: Isolated
Range: 5, 10, 15, 20, or 25 g’s (100 mv/g Input)
Constant Current Diode: 4.0 mA
Fault Indication: Green LED and 4-20 mA < 2mA
 
 
Optional Relay Module
Alarms: OK, Alert and Danger
Alarm Setpoints: Alert and Danger Adjustable 0 to 110% FS
Trip Multiply: 2X or 3X on Contact Closure
Alarm Relays: OK, Alert and Danger
Form C, SPDT, 5A @ 30 VDC or 250 VAC
Latching or Non-latching, Selectable
Time Delay: 0.1, 1, 3, 6 or 10 Seconds, Selectable
Alarm LED’s: Alert = Yellow, Danger = Red
Display Outputs: 0-5 VDC for Current Value, Alert Setpoint and Danger Setpoint
   
Environmental
Operating Temp.: -20°C to +80° C (-4° F to +176° F)
Storage Temp.: -55°C to +125° C (-67° F to +257° F)
Relative Humidity: 0 – 95% Non-Condensing
   
Physical
Mounting: 32 mm (G style) or 35 mm (T style) DIN Rail
Size: Transmitter 1.0″ Wide x 3.11″ High x 3.95″ Deep
w/Relay Module 1.6″ Wide x 3.11″ High x 3.95″ Deep
 

Enquire about CMCP525 Acceleration Transmitter/Monitor

    Send your inquiry via the form below or contact us: info@vims.pl, +48 12 446 40 50


    error

    Pozostań z nami w kontakcie | Let's keep in touch

    Facebook
    YouTube
    LinkedIn
    LinkedIn