Our advanced vibration transmitters, or loop powered sensors, are engineered for use with the latest PLC (programmable logic controller), BMS (building management system), or SCADA (supervisory control and data acquisition) technologies, offering sophisticated solutions for condition monitoring and preventative maintenance. The family is available with a variety of different cables.
Key Features:
4-20mA output proportional to ‘g’
Temperature (10mV/°C)
Various mountings
Sealed to IP67
Typical Applications:
Fans, pumps, motors, gearboxes, compressore, centrifuges, conveyors, Air handlers, rolls, dryers, presses, cooling, VAC, spindles, machine tooling, process equipment
Technical Performance
Mounted Base Resonance: 10kHz min
Velocity Ranges: see: ‘How To Order’ table ± 10% Nominal 80Hz at 22°C
Frequency Response: 10Hz (600cpm) to 5kHz (300kcpm) ± 5% – ISO10816
Isolation: Base isolated
Range: see: ‘How To Order’ table
Temperature Output: 10mV/ºC – 0-1V proportional to 32-212ºF
Transverse Sensitivity: Less than 5%
Mechanical
Case Material: Stainless Steel
Sensing Element/Construction: PZT/Compression
Mounting Torque: 8Nm
Weight: 150gms (nominal)
Sheilded Cable Assembly: see: www.hansfordsensors.com for options
Mounting Threads: see: ‘How To Order’ table
Electrical
Current Output: 4-20mA DC proportional to acceleration
Supply Voltage: 15-30 Volts DC (for 4-20mA)
Settling Time: 2 seconds
Output Impedance: Loop Resistance 600 Ohms max. at 24 Volts
Case Isolation: >108 Ohms at 500 Volts
Environmental
Operating Temperature Range: -25 to 90ºC
Sealing: IP67
Maximum Shock: 5000g
EMC: EN61326-1:2013
Typical Frequency Response (at 100mV/g):How to order:
Enquire about HS-422T Transmitter 4-20mA velocity- Side Entry- Dual Output (4-20mA & Temp)- M12